I took some pictures of the attic wiring at a clients home.
Run a new circuit plug in attic.
Running wires inside rigid conduit to run the wires inside rigid conduit you ll need a hacksaw a pipe bender capable of bending 1 2 in.
They say that the wiring was put in to add a few lights to bedrooms and it was inspected.
Instead of adding just a light.
Run the new cable with sheathing at least two inches up inside the box and double over the excess wires to help hold the cable in place.
I was going to buy an.
When running new wiring pay attention to the amp rating for the circuit you are extending.
For a 15 amp circuit use 14 awg american wire gauge cable for 20 amps use 12 awg 30 amp.
Of insulation off the ends and connect the wires from the new cable to the existing bundles white to white black to black ground to ground.
Most lighting and receptacle circuits will be 15 amps and make use of 14 2 or 14 3 but some of these circuits may.
10 awg 40 amps.
It looks like the circuits were added recently too.
Is this to code.
Size circuit breaker for wire size.
Tools materials required to run a new circuit wire strippers.
If a 14 2 cable is run from the panel to the outlet then a 15 amp circuit breaker is the largest that can be used to protect that circuit.
Otherwise you can connect to an existing circuit if the circuit has enough capacity and the box you re connecting to has enough volume for the additional wires.
I want to install some remote controlled security lights for my tenants.
The wiring is so close to the roof and run along the joists.
This is in ontario.
When extending a circuit for example the electrician may run the cable vertically from an existing outlet box up to the attic or down into the basement across joists to a spot directly above or below the new box location then into that wall cavity to the new electrical box opening.
The same principals apply to all 110v circuits and slightly modified instructions can be used for 240v circuits.
I have never seen attic wiring installed this way.
I can t afford to have an electrician do the whole thing so my plan was to put a receptacle in the attic near the breaker box above a bedroom and run wire from the receptacle to the floodlights at the end of the garage and an outlet placed near the floodlight inside the attic above the garage.
This article is focused on running a new circuit for light fixtures or outlets.
Less than 30 i needed a light desperately so i could see while moving around in the attic.
8 awg 50 to 60 amps.